Mostrar el registro sencillo del ítem
Autor | Carvalho, Juliana Machado de | |
Autor | Silva, Andrea R. da | |
Autor | Cunha, Alessandra L. M. C. da | |
Autor | Aucélio, Ricardo Q. | |
Autor | Albert, André Luis Mazzei | |
Autor | Leandro, Katia Christina | |
Fecha de acceso | 2014-11-13T11:59:36Z | |
Fecha de disponibilización | 2014-11-13T11:59:36Z | |
Fecha de publicación | 2012 | |
Referencia | CARVALHO, J. M. et al. Voltammetric determination of sibutramine in beverages and in pharmaceutical formulations. Química Nova, São Paulo, v. 35, n. 5, p. 988-992, 2012. | pt_BR |
ISSN | 0100-4042 | |
URI | https://www.arca.fiocruz.br/handle/icict/8821 | |
Resumen en Portugués | Um método simples e sensível foi proposto para a determinação de sibutramina -HCl em bebidas energéticas, chá verde e formulações farmacêuticas utilizando voltametria de pulso diferencial realizada em um eletrodo de gota pendente de mercúrio . Na condição experimental escolhido (tampão Mcllvaine pH 4.0, 50 mV de amplitude de pulso e 40 mV s- 1 velocidade de exploração ), a sibutramina -HCl apresentou um comportamento reversível e um pico máximo a -80 mV. O limite de detecção foi de 0,4 mg L - 1 e o intervalo linear de trabalho prolongado até 33,3 mg L -1 (r=0,99). A análise de amostras reais e fortificadas permitiu recuperações entre 91 e 102%. O método eletroanalítico foi comparado com um método de HPLC, que indicou a precisão. | pt_BR |
Idioma | eng | pt_BR |
Editor | Sociedade Brasileira de Química | pt_BR |
Derechos de autor | open access | pt_BR |
Palabras clave en Portugués | Sibutramina | pt_BR |
Palabras clave en Portugués | Voltametria de Pulso Diferencial | pt_BR |
Palabras clave en Portugués | Formulações Farmacêuticas | pt_BR |
Título | Voltammetric determination of sibutramine in beverages and in pharmaceutical formulations | en |
Tipo del documento | Article | pt_BR |
DOI | http://dx.doi.org/10.1590/S0100-40422012000500023 | |
Resumen en Inglés | A simple and sensitive method has been proposed for the determination of sibutramine-HCl in energy drinks, green tea and pharmaceutical formulations using differential pulse voltammetry performed on a hanging mercury drop electrode. In the chosen experimental condition (Mcllvaine pH 4.0 buffer, 50 mV pulse amplitude and 40 mV s-1 scan velocity), sibutramine-HCl presented a reversible behavior and a peak maximum at –80 mV. Detection limit was 0.4 mg L-1 and the working linear range extended up to 33.3 mg L-1 (r = 0.99). Analysis of real and fortified samples enabled recoveries between 91 and 102%. The electroanalytical method was compared with a HPLC method which indicated it accuracy. | en |
Afiliación | Pontifícia Universidade Católica do Rio de Janeiro. Rio de Janeiro, RJ, Brasil. | pt_BR |
Afiliación | Pontifícia Universidade Católica do Rio de Janeiro. Rio de Janeiro, RJ, Brasil. | pt_BR |
Afiliación | Pontifícia Universidade Católica do Rio de Janeiro. Rio de Janeiro, RJ, Brasil. | pt_BR |
Afiliación | Pontifícia Universidade Católica do Rio de Janeiro. Rio de Janeiro, RJ, Brasil. | pt_BR |
Afiliación | Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde. Departamento de Química. Rio de Janeiro, RJ, Brasil. | pt_BR |
Afiliación | Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde. Departamento de Química. Rio de Janeiro, RJ, Brasil. | pt_BR |
Palavras clave en Inglês | Sibutramine | en |
Palavras clave en Inglês | Differential Pulse Voltammetry | en |
Palavras clave en Inglês | Pharmaceutical Formulations | en |
DeCS | Depressores do Apetite | pt_BR |
DeCS | Polarografia | pt_BR |
DeCS | Preparações Farmacêuticas | pt_BR |
DeCS | Eletroquímica | pt_BR |