Please use this identifier to cite or link to this item: https://www.arca.fiocruz.br/handle/icict/3472
Title: Estudo da complacência e resistência do pulmäo e do sistema respiratório do recém-nascido a termo
Advisor: Lopes, José Maria de Andrade
Authors: Ramos, Jose Roberto de Moraes
Affilliation: Fundação Oswaldo Cruz. Instituto Fernandes Figueira. Departamento de Ensino. Programa de Pós-Graduação em Saúde da Criança. Rio de Janeiro, RJ, Brasil
Abstract: Estudamos 20 recém-nascidos a termo, durante o sono e medimos a complacência e resistência por 3 diferentes técnicas. Os valores de Complacência do pulmäo (CP) e Resistência do Pulmäo (RP) foram obtidos pelas técnicas de análise convencional (Mead-Wittemberger) e pela técnica de regressäo linear. Os valores da Complacência do Sistema Respiratório (CRS) e Resistência do Sistema Respiratório (RSR) foram obtidos pela técnica de análise de múltiplas oclusoes. Em 12 recém-nascidos foi possível a comparaçäo das 3 diferentes técnicas de análise e de que forma elas se correlacionavam. Apesar das medidas pulmonares serem diferentes das medidas do Sistema Respiratório, a elevada complacência da caixa torácica no recém-nascido permitiu a correlaçäo entre ambas medidas. Encontramos excelentes correlaçäo quando comparamos os valores de CP obtidos pelas técnicas de regressäo linear e de Mead-Wittemberger (r=0.97). Excelente correlaçäo também foi encontrada quando comparamos a RP por ambas técnicas (r = 0.98). Quando comparamos os valores obtidos para CSR pela técnica multiplas oclusoes com os valores de CP obtidos pela técnica convencional, encontramos boa correlaçäo (r = 0.85). Boa correlaçäo também foi encontrada quando comparamos a CSR com a CP obtida pela técnica de regressäo (r = 0.83). Já a comparaçäo da RSR com a RP obtidas pelas técnicas de regressäo e convencional näo forneceu correlaçoes significativas. Nos concluímos que CP e RP podem ser adequadamente medidas em recém-nascidos a termo, por duas técnicas diferentes. CRS mostrou ser uma boa estimativa da CP. RSR näo correlacionou com RP, näo podendo portanto ser utilizada para estimá-la.
Abstract: We studied twenty full term newborns during sleep. Lung compliance (CL) and Lung resistance (RL)values were obtained with conventional technique (Mead-Wittemberger) and regression analysis technique.Compliance of respiratory system (CRS) and resistance of respiratory system (RRS) were obtained using the multiple occlusion technique. The comparison of these three techniques was pssible only in twelve newborns. We found excellent correlation we compared CL values obtained with regression analysis and the conventional technique (r = 0.97). Excellent corretlation was also found when we compared RL with both technique (r = 0.98). CRS values obtained with multiple occlusion technique showed us good correlation(r = 0.85) when compared with CL values obtained with conventional technique. We also found good correlation when CRS were compared with CL obtained with regression analysis technique (r = 0.83).RL measured with the regression analysis did not correlated with RRS. We concluded that CL and RL can be adequately measured with the newborns in two different techinique. CRS is a good estimate of CL. RRS did not correlate with RL and cannot be used as an estimate.
DeCS: Complacência Pulmonar
Sistema Respiratório
Ventilação Pulmonar
Issue Date: 1994
Publisher: Instituto Fernandes Figueira
Citation: RAMOS, Jose Roberto de Moraes. Estudo da complacência e resistência do pulmäo e do sistema respiratório do recém-nascido a termo. 1994. 103 f. Dissertação (Mestrado em Saúde da Criança)-Instituto Fernandes Figueira, Fundação Oswaldo Cruz, Rio de Janeiro, 1994.
Date of defense: 1994-01
Place of defense: Rio de Janeiro/RJ
Department: Departamento de Ensino
Defense institution: Fundação Oswaldo Cruz. Instituto Fernandes Figueira
Program: Programa de Pós-Graduação em Saúde da Criança
Copyright: restricted access
Appears in Collections:IFF - Dissertações de Mestrado

Files in This Item:
File Description SizeFormat 
JOSE.pdf11.25 MBAdobe PDFThumbnail
View/Open



FacebookTwitterDeliciousLinkedInGoogle BookmarksBibTex Format mendeley Endnote DiggMySpace

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.