Author | Ziehe, Érica Mendonça | |
Author | Fernandes, Renata Buarque | |
Author | Macedo, Marta Ribeiro Valle | |
Author | Vieira, Valéria Michielin | |
Author | Moraes, Aurea Maria Lage de | |
Access date | 2015-06-08T14:01:54Z | |
Available date | 2015-06-08T14:01:54Z | |
Document date | 2014 | |
Citation | ZIEHE, Érica Mendonça et al. Determinação da contaminação fúngica do ar em Creches Públicas do Rio de Janeiro/RJ. Vigilância Sanitária em Debate, v.2, n.1, p.51-56, 2014. | pt_BR |
URI | https://www.arca.fiocruz.br/handle/icict/10708 | |
Abstract in Portuguese | Este artigo apresenta a avaliação quantitativa e qualitativa dos contaminantes ambientais de duas
creches no Estado do Rio de Janeiro. Uma das creches funciona em um andar do prédio administrativo
de um Hospital Federal e a outra foi instalada em uma edificação mais nova e construída para
essa função. Foram escolhidos três pontos de coleta na creche A e quatro pontos na creche B durante
as quatro estações do ano – primavera, verão, outono e inverno. Comparamos os ambientes internos
e avaliamos a variabilidade dos parâmetros entre as duas creches durante as estações. Os níveis de
contaminação eram próximos em ambas as creches. Foi observado que a maioria das áreas internas
avaliadas tinha o nível de contaminação igual ou superior à contaminação externa. | pt_BR |
Language | eng | pt_BR |
Publisher | Fundação Oswaldo Cruz | pt_BR |
Rights | open access | |
Subject in Portuguese | Qualidade do Ar | pt_BR |
Subject in Portuguese | Fungos do Ar | pt_BR |
Subject in Portuguese | Ambientes fechados | pt_BR |
Subject in Portuguese | Creches | pt_BR |
Title | Determinação da contaminação fúngica do ar em Creches Públicas do Rio de Janeiro/RJ | pt_BR |
Alternative title | Determination of air fungal contamination in public kindergartens in Rio de Janeiro/ RJ | pt_BR |
Type | Article | |
DOI | 10.3395/vd.v2i1.96 | pt_BR |
Abstract | This note presents measurements of fungal contaminants in two public nursery schools in Rio de Janeiro
state, Brazil. One of the nursery school operates in an adapted floor in a building that belongs
to the administrative sector of a federal hospital; the other is newer and was designed to be a nursery
school. Measurements were obtained for airborne fungi, temperature and relative humidity. Each of
these measurements was made in three points in nursery school A and four points in school B over
four seasons – spring, summer, fall and winter. We compared the indoor environments and examined
the variability in measured parameters between and within schools and across seasons. The level of
all measured parameters was comparable for the two schools. It was observed that in the majority of
the evaluated areas the indoor contamination was close to or superior to the outdoor contamination. | pt_BR |
Affilliation | Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Laboratório de Taxonomia, Bioquímica e Bioprospecção de Fungos. Rio de Janeiro, RJ, Brasil. | pt_BR |
Affilliation | Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Laboratório de Taxonomia, Bioquímica e Bioprospecção de Fungos. Rio de Janeiro, RJ, Brasil. | pt_BR |
Affilliation | Fundação Oswaldo Cruz. Coordenação de Saúde do Trabalhador (CST). Rio de Janeiro, RJ, Brasil. | pt_BR |
Affilliation | Fundação Oswaldo Cruz. Coordenação de Saúde do Trabalhador (CST). Rio de Janeiro, RJ, Brasil. | pt_BR |
Affilliation | Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Laboratório de Taxonomia, Bioquímica e Bioprospecção de Fungos. Rio de Janeiro, RJ, Brasil. | pt_BR |
Subject | Indoor Air | pt_BR |
Subject | Airbone Fungi | pt_BR |
Subject | Indoor Air Quality | pt_BR |
Subject | Nursery School | pt_BR |