Mostrar el registro sencillo del ítem
Autor | Villar, Livia Melo | |
Autor | Cruz, Helena Medina | |
Autor | Yoshida, Clara Fumiko Tachibana | |
Autor | Lampe, Elisabeth | |
Autor | Lewis-Ximenez, Lia Laura | |
Fecha de acceso | 2017-01-18T10:27:20Z | |
Fecha de disponibilización | 2017-01-18T10:27:20Z | |
Fecha de publicación | 2011 | |
Referencia | VILLAR, Livia Melo; et al. Assessment of Dried Blood Spot Samples as a Simple Method for Detection of Hepatitis B Virus Markers. Journal of Medical Virology, v.83, p.1522–1529, 2011. | pt_BR |
ISSN | 0146-6615 | pt_BR |
URI | https://www.arca.fiocruz.br/handle/icict/16881 | |
Idioma | eng | pt_BR |
Editor | Wiley | pt_BR |
Derechos de autor | restricted access | |
Palabras clave en Portugués | Vírus da Hepatite B | pt_BR |
Palabras clave en Portugués | filtro de papel | pt_BR |
Palabras clave en Portugués | Mancha de sangue seco | pt_BR |
Palabras clave en Portugués | Estudos de estabilidade | pt_BR |
Palabras clave en Portugués | ELISA | pt_BR |
Título | Assessment of dried blood spot samples as a simple method for detection of hepatitis B virus markers | pt_BR |
Tipo del documento | Article | |
DOI | 10.1002/jmv.22138 | |
Resumen en Inglés | Detection of hepatitis B virus (HBV) serological markers in dried blood spot (DBS) samples by enzyme immunoassay (ELISA) has not yet been fully optimized. In this study, the ability to detect three HBV markers (HBsAg, anti-HBc, and anti-HBs) was evaluated in DBS samples using a modified commercial ELISA. Matched serum and DBS samples were obtained from individuals with or without a past history of HBV infection. Sera samples were tested according to the manufacturer's instructions, but for DBS testing, paper diameters, elution buffer, volume of input sample, and cut-off values were evaluated to optimize the assay. Stability studies were done on DBS stored at for up to 180 days at different temperatures. The absorbance values that yielded the maximum sensitivity and specificity were determined based on the area under the ROC curve (AUROC) and chosen as the cut-off value. Using this parameter, sensitivity was 90.5%, 97.6%, and 78% for anti-HBc, HBsAg, anti-HBs assays, respectively. Specificity was 92.6%, 96.7%, and 97.3% for anti-HBc, HBsAg, and anti-HBs assays, respectively. HBV markers could be detected in DBS samples until 63 days after sample collection at most temperatures, but storage at -20°C yielded more consistent results. These results indicate that modified ELISA can be used to detect HBV markers in DBS samples, particularly if the samples are stored appropriately. | pt_BR |
Afiliación | Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Laboratório de Hepatites Virais. Rio de Janeiro, RJ. Brasil. | pt_BR |
Afiliación | Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Laboratório de Hepatites Virais. Rio de Janeiro, RJ. Brasil. | pt_BR |
Afiliación | Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Laboratório de Hepatites Virais. Rio de Janeiro, RJ. Brasil. | pt_BR |
Afiliación | Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Laboratório de Hepatites Virais. Rio de Janeiro, RJ. Brasil. | pt_BR |
Afiliación | Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Laboratório de Hepatites Virais. Rio de Janeiro, RJ. Brasil. | pt_BR |
Afiliación | Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Laboratório de Hepatites Virais. Rio de Janeiro, RJ. Brasil. | pt_BR |
Palavras clave en Inglês | HBV | pt_BR |
Palavras clave en Inglês | filter paper | pt_BR |
Palavras clave en Inglês | DBS | pt_BR |
Palavras clave en Inglês | stability studies | pt_BR |
Palavras clave en Inglês | ELISA | pt_BR |
e-ISSN | 1096-9071 | |
Fecha de embargo | 2030-01-01 |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
IOC - Artigos de Periódicos [12980]