Author | Aires, Eugenio P. Q. | |
Author | Almeida, Mônica G. | |
Author | Marques, Vitor M. | |
Author | Silva, Fernanda C. da | |
Author | Sá, Renato A. M. de | |
Author | Velarde, Guillermo C. | |
Access date | 2020-04-27T13:08:59Z | |
Available date | 2020-04-27T13:08:59Z | |
Document date | 2017 | |
Citation | AIRES, Eugenio P. Q. et al. A novel technique for the assessment of total liver blood flow in pregnancy: interrater and intrarater agreements. British Journal of Radiology, v. 90, n. 1074, p. 1-8, 2017. | pt_BR |
ISSN | 0007-1285 | pt_BR |
URI | https://www.arca.fiocruz.br/handle/icict/40978 | |
Abstract in Portuguese | Objetivo: Melhorar a técnica de exame do fluxo sanguíneo hepático, com o objetivo de investigar o papel da fluxometria Doppler do fígado no monitoramento de gestantes com pré-eclâmpsia. Métodos: Dois médicos examinaram independentemente um grupo de 50 mulheres grávidas saudáveis. A principal diferença na técnica proposta é a medida da área transversal do vaso e o ajuste das amostras Doppler de acordo com o diâmetro de cada vaso. A veia porta foi estudada usando duas abordagens: no epigástrio, para medir o diâmetro, e no intercostal, para coleta de amostras Doppler. A artéria hepática comum foi estudada usando a abordagem epigástrica. A média de três medições de cada navio, em cada sujeito, com acordos intra e interavaliadores, foi comparada.Resultados: O coeficiente de correlação intraclasse para as medições de fluxo intra-avaliador da artéria hepática e veia porta variou de 0,98 a 0,99 (p <0,0001). Os coeficientes de correlação intraclasse para as medidas de fluxo interobservadores foram de 0,93 para o fluxo da veia porta (p <0,0001), 0,94 para o fluxo da artéria hepática (p <0,0001) e 0,96 para a medida do diâmetro da veia porta (p < 0,0001). Conclusão: A nova técnica de avaliação do fluxo sanguíneo para o fígado apresentou excelente reprodutibilidade, possivelmente pelo ajuste das amostras Doppler de acordo com o diâmetro de cada vaso. Avanços no conhecimento: Essa abordagem adicionará confiabilidade ao método. Abre um vasto campo de investigação, dada a importância das lesões vasculares do fígado na pré-eclâmpsia. | pt_BR |
Language | eng | pt_BR |
Publisher | British Institute of Radiology. | pt_BR |
Rights | open access | |
MeSH | Blood Flow Velocity / physiology | pt_BR |
MeSH | Female | pt_BR |
MeSH | Hemodynamics / physiology | pt_BR |
MeSH | Humans | pt_BR |
MeSH | Image Interpretation, Computer-Assisted | pt_BR |
MeSH | Liver / blood supply | pt_BR |
MeSH | Liver / diagnostic imaging | pt_BR |
MeSH | Pregnancy | pt_BR |
MeSH | Reproducibility of Results | pt_BR |
MeSH | Ultrasonography, Doppler | pt_BR |
Title | A novel technique for the assessment of total liver blood flow in pregnancy: interrater and intrarater agreements | pt_BR |
Type | Article | pt_BR |
DOI | 10.1259/bjr.20160805 | |
Abstract | Objective: To improve the technique for hepatic blood flow examination, with the objective of investigating the role for Doppler flowmetry of the liver in monitoring pregnant females with pre-eclampsia. Methods: Two physicians independently examined a group of 50 healthy pregnant females. The main difference in the proposed technique is the measurement of the vessel cross-sectional area and the adjustment of the Doppler samples according to the diameter of each vessel. The portal vein was studied by using two approaches: in the epigastrium, to measure the diameter, and in the intercostal, for Doppler sample collection. The common hepatic artery was studied by using the epigastric approach. The average of three measurements of each vessel, in each subject, with intrarater and interrater agreements, was compared. Results: The intraclass correlation coefficient for the intrarater flow measurements of the hepatic artery and portal vein ranged from 0.98 to 0.99 (p < 0.0001). The intraclass correlation coefficients for the interrater flow measurements was 0.93 for the flow of the portal vein (p < 0.0001), 0.94 for the flow of the hepatic artery (p < 0.0001) and 0.96 for the measurement of the portal vein diameter (p < 0.0001).
Conclusion: The new technique for evaluation of blood flow to the liver displayed excellent reproducibility, possibly because of the adjustment of the Doppler samples according to the diameter of each vessel. Advances in knowledge: This approach will add reliability to the method. It opens a vast field of investigation given the importance of liver vascular lesions in pre-eclampsia. | pt_BR |
Affilliation | Universidade Federal do Estado do Rio de Janeiro. Departamento de Obstetrícia. Rio de Janeiro, RJ, Brasil / Escola de Ultrassonografia do Rio de Janeiro. Rio de Janeiro, RJ, Brasil. | pt_BR |
Affilliation | Universidade Federal Fluminense. Departamento de Obstetrícia. Niterói, RJ, Brasil. | pt_BR |
Affilliation | Universidade Federal do Estado do Rio de Janeiro. Departamento de Obstetrícia. Rio de Janeiro, RJ, Brasil / Escola de Ultrassonografia do Rio de Janeiro. Rio de Janeiro, RJ, Brasil. | pt_BR |
Affilliation | Universidade Federal do Estado do Rio de Janeiro. Departamento de Obstetrícia. Rio de Janeiro, RJ, Brasil / Grupo Perinatal. Departamento de Obstetrícia. Rio de Janeiro, RJ, Brasil. | pt_BR |
Affilliation | Fundação Oswaldo Cruz. Instituto Nacional de Saúde da Mulher, da Criança e do Adolescente Fernandes Figueira, Departamento de Pesquisa. Rio de Janeiro, RJ, Brasil / Universidade Federal Fluminense. Departamento de Estatística. Niterói, RJ, Brasil. | pt_BR |
Affilliation | Universidade Federal Fluminense. Departamento de Estatística. Niterói, RJ, Brasil. | pt_BR |
Subject | Novel technique | pt_BR |
Subject | Total liver blood flow | pt_BR |
Subject | Pregnancy | pt_BR |