Please use this identifier to cite or link to this item: https://www.arca.fiocruz.br/handle/icict/11913
Title: Confiabilidade teste-reteste do Índice de Capacidade para o Trabalho (ICT) em trabalhadores de enfermagem
Other Titles: Test-retest reliability of the Work Ability Index (WAI) in nursing workers
Authors: Silva Junior, Sérgio Henrique Almeida da
Vasconcelos, Ana Glória Godoi
Griep, Rosane Härter
Rotenberg, Lúcia
Affilliation: Fundação Oswaldo Cruz. Escola Nacional de Saúde Pública Sérgio Arouca. Rio de Janeiro, RJ, Brasil.
Fundação Oswaldo Cruz. Escola Nacional de Saúde Pública Sérgio Arouca. Rio de Janeiro, RJ, Brasil.
Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Rio de Janeiro, RJ, Brasil.
Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Rio de Janeiro, RJ, Brasil.
Abstract: Este artigo avalia a confiabilidade teste- -reteste do Índice de Capacidade para o Trabalho (ICT) em trabalhadores de enfermagem. Foi aplicado questionário autopreenchível duas vezes a um grupo de 80 trabalhadores de enfermagem (enfermeiros, técnicos e auxiliares de enfermagem) de um hospital público no Município do Rio de Janeiro, com intervalo entre sete e quinze dias. A confiabilidade foi estimada pela estatística kappa ponderada quadrática, pelo coeficiente de correlação intraclasse (CCI) e pelo gráfico de Bland e Altman. Dos participantes, 81% eram mulheres e com idade variando de 22 a 67 anos (média = 39,1; DP = 10,8anos) e 36,3% tinham ensino superior completo. O escore global do ICT apresentou CCI = 0,79 (IC95% 0,67 a 0,86) e kappa = 0,69 (IC95% 0,50 a 0,80) para o ICT categórico (classificado em baixo, moderado, bom e ótimo). O kappa dos itens do ICT variou de 0,39 a 0,82 e o gráfico de Bland e Altman não mostrou um padrão sistemático. A concordância entre as medidas de teste-reteste indica grau aceitável de confiabilidade, sugerindo adequação do processo de aferição entre trabalhadores de enfermagem.
Abstract: This paper assesses the test retest reliability of the Work Ability Index (WAI) in nursing workers. A self-administered questionnaire was applied twice to a group of 80 workers (nurses and nursing aides/assistants) at a public hospital in Rio de Janeiro, Brazil within an interval from seven to fifteen days. The reliability was estimated using quadratic weighted kappa statistics, interclass correlation coefficient (ICC) and the Bland and Altman plot. Eighty-one percent of participants were women aged betweenfrom 22 to 67 years (mean =39.1; SD=10.8 years); 36.3% had completed higher education. The global score of the WAI presented ICC= 0.79 (IC95% 0.67 to 0.86) and weighted kappa=0.69 (CI95% 0.50 to 0.80) for categorical WAI (classified as low, moderate, good and excellent). The quadratic weighted kappaof the WAI items ranged from 0.39 to 0.82 and the Bland and Altman plot did not show a systematic pattern. The agreement between the test and retest measures shows an acceptable degree of reliability, suggesting the adequacy of the assessment process among nursing workers.
Keywords: Reliability
Work ability
Nursing
Kappa
Interclass Correlation Coefficient (ICC)
Bland and Altman graphic
keywords: Confiabilidade
Capacidade para o trabalho
Enfermagem
Kappa
Coeficiente de Correlação Intraclasse
Gráfico de Bland e Altman
Issue Date: 2013
Publisher: Associação Brasileira de Pós-Graduação em Saúde Coletiva
Citation: SILVA JUNIOR, Sérgio Henrique Almeida da; et al. Confiabilidade teste-reteste do Índice de Capacidade para o Trabalho (ICT) em trabalhadores de enfermagem. Rev. Bras. Epidemiol., v.16, n.1, p. 202-209, 2013.
ISSN: 1415-790X
Copyright: open access
Appears in Collections:ENSP - Artigos de Periódicos
IOC - Artigos de Periódicos

Files in This Item:
File Description SizeFormat 
lucia_rotenberg2_etal_IOC_2013.pdf325.18 kBAdobe PDFView/Open


FacebookTwitterDeliciousLinkedInGoogle BookmarksBibTex Format mendeley Endnote DiggMySpace

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.