Please use this identifier to cite or link to this item:
https://www.arca.fiocruz.br/handle/icict/16310
Type
ArticleCopyright
Open access
Collections
- ENSP - Artigos de Periódicos [2412]
- IOC - Artigos de Periódicos [12978]
Metadata
Show full item record
VALIDEZ Y CONFIABILIDAD DEL ÍNDICE DE CAPACIDAD PARA EL TRABAJO EN TRABAJADORES DEL PRIMER NIVEL DE ATENCIÓN DE SALUD EN ARGENTINA
Alternative title
Validity and reliability of the Work Ability Index in primary care workers in ArgentinaAffilliation
Instituto Nacional de Epidemiologia “Dr. Juan H. Jara. Departamento de Vigilancia y Clínica Epidemiológica. Argentina.
Fundação Oswaldo Cruz. Escola Nacional de Saúde Pública Sérgio Arouca. Programa de Epidemiología em Saúde Pública. Rio de Janeiro, RJ, Brasil.
Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Laboratório de Educação em Ambiente e Saúde. Rio de Janeiro, RJ, Brasil.
Instituto Nacional de Epidemiologia “Dr. Juan H. Jara. Departamento de Enseñanza Especializada. Argentina.
Fundação Oswaldo Cruz. Escola Nacional de Saúde Pública Sérgio Arouca. Programa de Epidemiología em Saúde Pública. Rio de Janeiro, RJ, Brasil.
Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Laboratório de Educação em Ambiente e Saúde. Rio de Janeiro, RJ, Brasil.
Instituto Nacional de Epidemiologia “Dr. Juan H. Jara. Departamento de Enseñanza Especializada. Argentina.
Abstract
This study evaluates the validity and reliability of the Work Ability Index
(WAI) in Argentina. An instrument was applied to 100 workers, all agents of Primary Health
Care in the county of General Pueyrredón. In the construct validity, the dimensional
structure was studied by means of exploratory factor analysis, based on a polychoric
matrix and parallel analysis to obtain the number of factors. In the correlation validation,
the Spearman correlation was estimated between the WAI and the dimensions of the 36-
Item Short Form Health Survey (SF-36). The reliability assessment was measured by
Cronbach's alpha estimate. The result of the internal consistency of the scale was 0.80,
indicating acceptable reliability. The WAI score yielded the following results: 12%
moderate, 50% good and 38% optimal. In the validation process, a three-dimensional
structure was identified which accounts for 66% of the total variance of the data through
the main components. The theoretical assumptions of the construct validity confirmed the
direct and significant correlation between WAI scores and the dimensions of health status
assessment, with the highest value in the physical functioning dimension (0.478) and the
lowest in the bodily pain dimension (-0.218). It was concluded that the WAI, translated
and adapted into Spanish, showed adequate psychometric properties and can therefore be
used in association studies between aspects of work and their impact on health.
xmlui.dri2xhtml.METS-1.0.item-abstractes
Este estudio evalúa la validez y confiabilidad del Índice de Capacidad para el
Trabajo (ICT) en Argentina. El instrumento se aplicó a 100 trabajadores, agentes de
Atención Primaria de la Salud del Partido de General Pueyrredón. En la validez del constructo
se investigó la estructura dimensional por medio de análisis factorial exploratorio, a
partir de una matriz policórica y un análisis paralelo para la obtención del número de factores.
En la validación correlacional se estimó la correlación de Spearman entre el ICT y
las dimensiones del Cuestionario de Salud SF-36. La evaluación de confiabilidad se midió
a través del estimador Alfa de Cronbach. El resultado de la consistencia interna de la escala
fue 0,80, indicando una fiabilidad aceptable. La puntuación de ICT arrojó como resultado:
moderado 12%, bueno 50% y óptimo 38%. En el proceso de validación se identificó
una estructura de tres dimensiones que explica el 66% de la variación total de los datos
a través de los componentes principales. Los supuestos teóricos de la validez del constructo
confirmaron la correlación directa y significativa con las puntuaciones del ICT y las
dimensiones de evaluación del estado de salud, siendo el mayor valor función física
(0,478) y menor la dimensión dolor (-0,218). Se concluyó que el ICT, traducido y adaptado
al español, mostró propiedades psicométricas adecuadas pudiendo ser utilizada en
estudios de asociación entre aspectos de trabajo y su impacto en la salud.
Share