Please use this identifier to cite or link to this item:
https://www.arca.fiocruz.br/handle/icict/2426
DETERMINAÇÃO DOS NÍVEIS DE ESTANHO EM FLUIDOS BIOLÓGICOS DE POPULAÇÃO EXPOSTA AMBIENTALMENTE NA VILA MASSANGANA, RO
Urine
Toxicity
Environmental Exposure
Spectrophotometry, Atomic
Mining
Occupational Exposure
Environmental Pollution
Urban Health
Urina
Toxicidade
Exposição Ambiental
Espectrofotometria Atômica
Mineração
Exposição Ocupacional
Poluição Ambiental
Saúde da População Urbana
Sangue
Azevedo, Sayonara Vieira de | Date Issued:
2009
Alternative title
Determination of levels of tin in biological fluids of environmentally exposed population in the Village Massangana, ROAuthor
Advisor
Affilliation
Fundação Oswaldo Cruz. Escola Nacional de Saúde Pública Sergio Arouca. Rio de Janeiro, RJ, Brasil.
Abstract in Portuguese
O estanho é um elemento natural na crosta terrestre, amplamente utilizado na indústria
pelo baixo ponto de fusão, formação de ligas, resistência à corrosão e oxidação. A
exposição ao metal e seus compostos pode produzir diversos efeitos nos sistemas neuro,
hemato e imunológicos, além de danos ao fígado e rins, entre outros. O objetivo desse
trabalho foi a avaliação da exposição ao estanho dos indivíduos residentes na Vila
Massangana. Para tal, metodologias para determinação do estanho em sangue e urina
foram desenvolvidas (ET AAS). A mesma temperatura ótima de pirólise (1300°C) foi
alcançada com ambas as matrizes, enquanto que a de atomização ficou em 2100°C e
2200ºC para sangue e urina, respectivamente. A maior sensibilidade foi alcançada na
diluição de 7X para sangue, bem como 5X na urina, ambos diluídos em Triton X-100
0,1% (v/v). A eficiência de três diferentes massas do modificador a base de Pd e Mg foi
estudada e a melhor sensibilidade foi encontrada com 10!g Pd + 6!g Mg e 15!g Pd +
10!g Mg para ambas as matrizes. O estanho se mostrou linear até a faixa de 50 µg Sn L1
para curvas em sangue e urina, que mostraram a existência de efeito de matriz, 0,81 ±
0,06 e 1,32 ± 0,04, respectivamente. O limite de detecção (3") calculado para a urina foi
0,8 ± 0,1 µg L-1 e, para o sangue total, ficou em 2,7 ± 0,5 µg L-1, o que permite a
determinação de estanho em sangue e urina de pessoas não expostas ambientalmente. A
exatidão foi verificada pela análise de materiais de referência. Para a urina, foi utilizada
a amostra Seronorm Urine (54,6 ± 2,7 µg L-1), tendo como resultado 54,3 ± 1,6,
enquanto que o Contox I Serum (3,0 ± 2 µg L-1) foi utilizado para o sangue, cujo
resultado foi 2,90 ± 1,2. Após a validação, a concentração de estanho foi determinada
em amostras de sangue e urina de 22 indivíduos (sangue: 10,5 ± 1,7 µg L-1; urina; 3,2 ±
1,1 µg L-1) da população de Vila Massangana e 11 pessoas (sangue: 8,4 ± 1,2 µg L-1;
urina; 1,0 ± 0,5 µg L-1) do grupo controle. Houve diferença estatisticamente
significativa (p<0,05) entre esses dois grupos, mostrando a existência de exposição
ambiental.
Abstract
Tin is a natural element in the earth's crust, widely used in industry due to some
characteristics like low melting point, production of alloys and resistance to corrosion
and oxidation. Exposure to tin metal and its compounds may produce different effects
on neural, hemato and immunological systems as well as damage to the liver and
kidneys, among others. The aim of this work was the exposure assessment to tin for the
population from Vila Massangana. To this end, methodologies for the determination of
tin in blood and urine were developed (ET AAS). The same optimum pyrolysis
temperature (1300°C) were achieved with both matrices, while the optimum
atomization temperature was 2100°C and 2200°C for blood and urine, respectively. The
highest sensitivity was achieved in the dilution of 7X for blood and urine 5X, both
diluted in 0.1% (v / v) Triton X-100. The efficiency of three different masses of the
modifier (Pd and Mg) was studied and the best sensitivity was reached using 10 !g Pd +
6 !g Mg and 15 !g Pd + 10 !g Mg for both matrices. Tin showed linearity up to 50 !g
Sn L-1 for curves in blood and urine, which showed the existence of the matrix effects,
0.81 ± 0.06 e 1.32 ± 0.04, respectively. The limit of detection (3") was 0.8 ± 0.1 µg L-1
for urine and 2.7 ± 0.5 µg L-1 for whole blood, which allows the determination of tin in
blood and urine of the population not exposed environmentally. The accuracy was
verified by analysis of reference materials. For urine, Seronorm Urine (54.6 ± 2.7 µg L1
) was used and the result was 54.3 ± 1.6, while Contox I Serum (3,0 ± 2 µg L-1) was
used for blood, resulting in 2.9 ± 1.2 µg L-1 . After validation, tin concentration was
determined in whole blood and urine samples of 22 individuals (blood: 10.5 ± 1.7 µg L1
, urine: 3.2 ± 1.1 µg L-1) living in Vila Massangana and 11 people (blood: 8.4 ± 1.2 µg
L
-1; urine: 1.0 ± 0.5 µg L-1) in the control group. There was a statistically significant
difference (p <0.05) between these two groups, showing the existence of environmental
exposure. There was a statistically significant difference (p <0.05) between these two
groups, showing the existence of environmental exposure.
Keywords
TinUrine
Toxicity
Environmental Exposure
Spectrophotometry, Atomic
Mining
Occupational Exposure
Environmental Pollution
Urban Health
Keywords in Spanish
BloodDeCS
EstanhoUrina
Toxicidade
Exposição Ambiental
Espectrofotometria Atômica
Mineração
Exposição Ocupacional
Poluição Ambiental
Saúde da População Urbana
Sangue
Share