Please use this identifier to cite or link to this item:
https://www.arca.fiocruz.br/handle/icict/26545
Type
ArticleCopyright
Restricted access
Embargo date
2024-01-01
Collections
Metadata
Show full item record
ROTARY INSTRUMENT OR PIEZOELECTRIC FOR THE REMOVAL OF THIRD MOLARS: A META-ANALYSIS.
Author
Affilliation
Universidade Federal dos Vales do Jequitinhonha e Mucuri. Faculdade de Ciências Básicas e da Saúde. Departamento de Odontologia. Diamantina, MG Brazil.
Fundação Oswaldo Cruz. Instituto René Rachou. Belo Horizonte, MG, Brazil
Universidade Federal de Minas Gerais. Departamento de Odontologia e Ortodontia Pediatrica. Belo Horizonte, MG, Brazil
Universidade Federal dos Vales do Jequitinhona e Mucuri. Departamento de Odontologia. Diamantina, MG, Brazil
Universidade Federal dos Vales do Jequitinhona e Mucuri. Departamento de Odontologia. Diamantina, MG, Brazil
Fundação Oswaldo Cruz. Instituto René Rachou. Belo Horizonte, MG, Brazil
Universidade Federal de Minas Gerais. Departamento de Odontologia e Ortodontia Pediatrica. Belo Horizonte, MG, Brazil
Universidade Federal dos Vales do Jequitinhona e Mucuri. Departamento de Odontologia. Diamantina, MG, Brazil
Universidade Federal dos Vales do Jequitinhona e Mucuri. Departamento de Odontologia. Diamantina, MG, Brazil
Abstract
AIM: The aim of this systematic review and meta-analysis was to compare, in the lower third molar surgery, the osteotomy techniques with rotary instruments and piezoelectric motors.
METHODS: An electronic search was conducted using the following databases: Pubmed, Web of Science, and the Cochrane Oral Health Group Trials Register. Inclusion criteria were: studies in humans, randomized or nonrandomized, comparing the extraction of third molars that required osteotomy and/or odontosection with rotary instrument and osteotomy and/or odontosection with piezoelectric motor assistance. The analysis and inclusion of articles was performed by two reviewers independently. An evaluation of the quality of articles and data extraction was carried out.
RESULTS: From a total of nine hundred seventy four (974) trials, eleven articles were included in the qualitative analysis, and seven were included in the quantitative analysis. Rotary instruments were faster than the piezoelectric surgery (95 % CI 0.34 to 1.16). The piezoelectric surgery showed better results when compared with roatry instruments when trismus was assessed in 2 (95 % CI 0.65 to 1.69), 3 (95 % CI 0.63 to 1.67) and 5 (95 % CI 0.03 to 2.26) days after surgery. Seven days after surgery, there were no differences between the techniques (95 % CI (-0.022) to (-1.49)).
CONCLUSION: The piezoelectric surgery was effective in reducing pain, swelling and trismus in third molar surgery, but the same requires greater surgical time than the rotary instruments.
Share