Please use this identifier to cite or link to this item:
https://www.arca.fiocruz.br/handle/icict/54644
AVALIAÇÃO DA ACURÁCIA DE DIFERENTES TESTES LABORATORIAIS NO DIAGNÓSTICO DA FILARIOSE EM CRIANÇAS E ADOLESCENTES
Masculino
Feminino
Pré-Escolar
Criança
Adolescente
Elefantíase FilarialDiag
Elisa
Anticorpos Anti-HelminticosSangue
Antígenos de HelmintosSangue
Filtração Por Membranas
Testes Laboratoriais
MicrofilariaIsol
Elefantíase FilarialSangue
Wuchereria BancroftiImunol
Wuchereria BancroftiIsol
Oliveira, Paula Alexandra dos Santos | Date Issued:
2010
Alternative title
Evaluation of the accuracy of different laboratory tests for the diagnosis of filariasis in children and adolescentsComittee Member
Affilliation
Fundação Oswaldo Cruz. Instituto Aggeu Magalhães. Rio de Janeiro, RJ, Brasil.
Abstract in Portuguese
Apesar de a filariose linfática (FL) ser considerada uma doença de adultos, estima-se que 22
milhões de crianças <15 anos de idade estejam infectadas no mundo. A Organização Mundial
da Saúde tem recomendado o monitoramento da infecção nessa população. Este estudo teve
como objetivo comparar a acurácia dos métodos parasitológicos e imunológicos no
diagnóstico da filariose bancroftiana em escolares. O estudo foi desenvolvido em escolares,
com idade entre 4 e 15 anos, residentes em três bairros do município de Olinda –
Pernambuco, Brasil. As amostras de sangue capilar e venoso foram coletadas entre 23:00 e
1:00 hora da manhã. Em seguida, as amostras de sangue venoso foram guardadas para
posterior realização das técnicas de filtração, concentração de Knott, Og4C3 - ELISA.
Amostras de sangue capilar foram obtidas para confecção das lâminas de gota espessa e
realização do teste rápido de imunocromatografia (ICT). As médias de densidade de
microfilaremia foram calculadas em escala logarítmica. A acurácia dos testes foi avaliada em
relação ao padrão-ouro (filtração). A especificidade do Og4C3 e ICT foi estimada utilizando a
equação de Staquet et al. (1981). Um total de 805 escolares foi examinado. As médias de
antigenemia filarial foram mais elevadas entre as crianças residentes nos bairros de alto da
conquista e alto da bondade. As cargas parasitárias e os níveis de antigenemia não variaram
com idade e sexo. A prevalência de microfilaremia pela técnica de filtração, de 5,2%, foi a
mais elevada em relação às demais técnicas parasitológicas. A prevalência de antigenemia
filarial pelo teste Og4C3 foi de 17,4%. Na comparação da acurácia dos testes em relação ao
padrão-ouro, as técnicas de gota espessa e Knott apresentaram valores de sensibilidade de
85,2%, inferiores aos testes ICT e Og4C3, que foi de 100%. Conclui-se que as técnicas de
filtração e Og4C3 são as mais apropriadas para a avaliação de transmissão em áreas com
programas de eliminação em andamento.
Abstract
Although lymphatic filariasis be considered a disease adults, it is estimated that 22 million
children <15 years old are infected worldwide. The World Health Organization
has recommended monitoring of infection in this population. This study aimed to compare the
accuracy of methods parasitological and immunological diagnosis of filariasis bancroftiana
schoolchildren. The study was conducted in school children, aged between 4 and 15 years
living in three neighborhoods of the city of Olinda-Pernambuco, Brazil. Samples capillary and
venous blood were collected between 23:00 and 1:00 hours of the morning. Thereafter,
venous blood samples were saved for later completion of filtration techniques, concentration
of Knott, Og4C3 - ELISA. Capillary blood samples were obtained to make the slides of blood
smear and testing from immunochromatography (ICT). The average density of
microfilaraemia was calculated on a scale logarithmic. The accuracy of the tests was
evaluated in relation to gold standard (filtration). The specificity of ICT and was
Og4C3 estimated using the equation of Staquet et al.0 (1981). A total of 805 school children
were checked. The averages of filarial antigenemia were higher among children living in
neighborhoods of high of high achievement and kindness. The worm burdens
and antigenemia levels did not vary with age and sex. The prevalence of microfilaraemia by
the filtration technique of 5.2% was the highest compared to other
techniques parasitological. The prevalence of filarial antigenemia by Og4C3 test was
17.4%. In comparing the accuracy of the tests compared to the gold standard, the techniques
of blood smear and Knott showed sensitivity of 85.2%, lower than ICT tests and Og4C3,
which was 100%. We conclude that the techniques filtration and Og4C3 are most appropriate
for evaluating transmission in areas with elimination programs in progress.
DeCS
HumanosMasculino
Feminino
Pré-Escolar
Criança
Adolescente
Elefantíase FilarialDiag
Elisa
Anticorpos Anti-HelminticosSangue
Antígenos de HelmintosSangue
Filtração Por Membranas
Testes Laboratoriais
MicrofilariaIsol
Elefantíase FilarialSangue
Wuchereria BancroftiImunol
Wuchereria BancroftiIsol
Share