Author | Silva, Cristiane Caldeira da | |
Author | Presgrave, Octavio Augusto França | |
Author | Moraes, Aurea Maria Lage de | |
Author | Delgado, Isabella Fernandes | |
Access date | 2016-05-02T18:46:19Z | |
Available date | 2016-05-02T18:46:19Z | |
Document date | 2012 | |
Citation | SILVA, C C. et al. Avaliação microbiológica da qualidade do ar de interiores: aspectos metodológicos e legais. Univ., Cienc. Saúde, Brasília, v. 10, n. 1, p. 51-60, 2010. | pt_BR |
ISSN | 1678-5398 | |
URI | https://www.arca.fiocruz.br/handle/icict/14077 | |
Abstract in Portuguese | A contaminação microbiológica do ar de interiores é um grave problema de saúde pública por estar associada a alergias e a doenças respiratórias. O objetivo desta revisão foi apresentar e discutir os métodos utilizados na avaliação microbiológica da Qualidade do Ar de Interiores (QAI) e os aspectos legais em relação aos Valores Máximos Recomendáveis (VMR). A amostragem ativa por impactação em meio sólido tem sido o método mais utilizado, entretanto, diferenças metodológicas contribuem para a dificuldade de padronização dos VMR. Os testes in vitro são considerados uma nova ferramenta para esse tipo de avaliação, entretanto, faltam estudos que utilizem tais métodos para todos os tipos de ambientes. As limitações da Resolução RE nº 9/2003 indicam a necessidade de uma nova legislação principalmente para serviços de saúde. | pt_BR |
Language | por | pt_BR |
Publisher | Centro Universitário de Brasília | pt_BR |
Rights | open access | pt_BR |
Subject in Portuguese | Poluição do Ar de Interiores | pt_BR |
Subject in Portuguese | Monitoramento Ambiental | pt_BR |
Subject in Portuguese | Bioaressóis | pt_BR |
Subject in Portuguese | Vigilância Sanitária | pt_BR |
Title | Avaliação microbiológica da qualidade do ar de interiores: aspectos metodológicos e legais | pt_BR |
Alternative title | Microbiological evaluation of indoor air quality: legal and methodological aspects | en |
Type | Article | pt_BR |
DOI | http://dx.doi.org/10.5102/ucs.v10i1.1656 | |
Abstract | The microbial indoor air contamination is a serious public health problem since it is associated with allergies and respiratory diseases. This review aimed to present and discuss different methods used to evaluate the microbiological indoor air quality (IAQ) and the legal aspects related to maximum acceptable levels (MAL). Active air sampling by impactor sampler on a solid medium has been the most widely used method, however, differences between methods and difficulties in recovery of microorganisms contribute to the difficulty of standardizing MAL. The in vitro tests are considered a new tool for this type of evaluation, however, there are few studies that use these methods for all types of environments. The limitations of the Act nº 9/2003 indicate the need for new legislation mainly for health. | en |
Affilliation | Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde. Departamento de Farmacologia e Toxicologia. Rio de Janeiro, RJ, Brasil. | pt_BR |
Affilliation | Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde. Departamento de Farmacologia e Toxicologia. Rio de Janeiro, RJ, Brasil. | pt_BR |
Affilliation | Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Rio de Janeiro, RJ, Brasil. | pt_BR |
Affilliation | Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde. Departamento de Farmacologia e Toxicologia. Rio de Janeiro, RJ, Brasil. | pt_BR |
Subject | Air Pollution, Indoor | en |
Subject | Environmental Monitoring | en |
Subject | Bioaerosol | en |
Subject | Sanitary Surveillance | en |
DeCS | Poluição do Ar em Ambientes Fechados | pt_BR |
DeCS | Monitoramento Ambiental | pt_BR |
DeCS | Aerossóis | pt_BR |
DeCS | Vigilância Sanitária | pt_BR |
xmlui.metadata.dc.subject.ods | 03 Saúde e Bem-Estar | |